BSP-2 Single Point Loadcell
- Single point loadcell
- C3 Class
- Capacity: 100-150-200-300-500kg
- Stainless Steel
- IP67 Protection
- Max base dimensions: 800mm x 800mm
- Suitable for single point platforms, test equipment, checkweighers.
Technical Table
Accuracy Class | C3 | |
Output Sensitivy (=FS) | mV/V | 2.0 ± 0.2 |
Maximum Capasity (Emax) | kg | 100,150, 200, 300,500 |
Max. Number of Load Cell Intervals | nLC | 3000 |
Ratio of Min. LC Verification Interval | Y= Emax / Vmin | 10000 |
Combined Error | %FS | ≤± 0.023 |
Safe Overload | % Emax | 150% |
Ultimate Overload | % Emax | 300% |
Zero Balance | %FS | < ± 2 % |
Excitation , Recommended Voltage | V | 5 ~ 12 |
Excitation Maximum (Umax) | V | 18 |
Input Resistance | Ω | 350 ± 3.5 |
Output Resistance | Ω | 350 ± 10 |
Insulation Resistance | MΩ | ≥5000 ( at 50VDC ) |
Compensated Temperature | °C | -10 ~+40 |
Operating Temperature | °C | -35 ~ +65 |
Element Metarial | °C | Stainless Steel |
Ingress Protection | IP67 | |
Recommended Torque on Fixation | Nm | M6: 10 M8:25 |
Cable | mm | 4x0,22 |